Error Items
|
LED
|
TROUBLE
|
TESTING
|
| I/M-SENSOR (R on Twin I/M units) |
 |
Ice Maker Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| R-SENSOR |
 |
Refrigerator Room Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| DEFROST SENSOR OF R ROOM |
 |
Ref. Defrost Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| R-FAN ERROR |
 |
This error indicates the Refrigerator Evap Fan is not spinning at the correct RPM or the fan feedback line is open. |
Fan voltage at MAIN PCB shall be between 7V~12V |
| I/M FUNCTION ERROR(R on Twin I/M) |
 |
This error indicates the Ice tray has not returned to level after an ice harvest. The error is displayed after three failed attempts. |
Replace I/M |
| R-DEFROSTING ERROR |
 |
Refrigerator Room defrost heater- open or short-circuit, connector failure, or defective temperature fuse/bi-metal. Defrost on over 80 minutes. |
Disconnect defrost connector from PCB, check resistance |
| PANTRY-DAMPER HEATER ERROR |
 |
Sensor system in Pantry Room errors. |
Disconnect heater connector from PCB, check resistance. |
| PANTRY-SENSOR ERROR |
 |
CR Room Sensor Error- This can be an open or short-circuit, contact failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage of MAIN PCB Sensor between 4.5V~1.0V |
| WATER HEATER ERROR |
 |
Error is displayed when the water reservoir tank heater is open or shorted. Disconnect heater connector from PCB, check resistance. |
Disconnect heater connector from PCB, check resistance. |
| EXT-SENSOR |
 |
Ambient Temp. Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| F-SENSOR |
 |
Freezer Compartment Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| F-DEF-SENSOR |
 |
Freezer Room Defrost Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| F-FAN ERROR |
 |
This error indicates the Freezer Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. |
Fan voltage at MAIN PCB shall be between 7V~12V |
| C-FAN ERROR |
 |
This error indicates the Condenser Fan is not spinning at the correct RPM or the fan feedback line is open. |
Fan voltage at MAIN PCB shall be between 7V~12V |
| FRENCH DOOR ICE ROOM SENSOR |
 |
Ice Room Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. |
The voltage at MAIN PCB Sensor between 4.5V~1.0V |
| F-DEFROSTING ERROR |
 |
Freezer defrosting heater- open or short-circuit, connector failure, or defective temperature fuse/bi-metal. Defrost on for over 80 minutes. |
Disconnect defrost connector from PCB, check resistance. |
| FRENCH DOOR ICE ROOM FAN ERROR |
 |
This error indicates the Ice Room Compartment Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. |
Fan voltage at MAIN PCB shall be between 7V~12V |
| Uart ERROR COMMUNICATION |
 |
This error is not applicable, if the error is detected during diagnostic testing please ignore it. |
No Repair Necessary |
| L.M ERROR COMMUNICATION |
 |
Communication error within the Main PCB |
Replace main PCB |
| P.M ERROR COMMUNICATION |
 |
Communication between the Main PCB and Keypad. |
Check wiring in door & cabinet, Panel PCB, Main PCB |